One box that charges your house battery from the alternator, solar and shore power at the same time.

The REDARC Manager Alpha75 is a complete 12V battery management system. It delivers up to 75A of combined charge from vehicle (DC), shore (AC) and solar, and puts solar first to take load off your alternator. The included RedVision display and Smart Battery Monitor show state of charge, time remaining and current flow, on the screen or in the RedVision app.

Fits: universal, any van, RV, truck or trailer with a 12V house battery. Not compatible: 24V or 48V house battery systems.

  • 75A simultaneous charging from DC, AC and solar, with solar prioritized
  • Works with lithium and lead acid: standard and heated lithium, AGM, gel, calcium and standard lead acid profiles
  • Start battery support: sends spare solar to your start battery and can recover a flat one
  • RedVision display and app with a Smart Battery Monitor measuring up to ±500A, Bluetooth 5.1 range up to 138 ft
  • Compact: 15.75 x 6.06 x 4.72 in and 13.25 lb, made in Australia, 2-year warranty

Pair it with a 206Ah heated lithium battery and a REDARC 3000W inverter. Need more charging? See the Manager Alpha100.

See it on your van. Add the REDARC MANAGER ALPHA75 WITH REDVISION to your build in our 3D Van Builder and preview it on a real Sprinter before you buy.

Product Details

Why we use the Manager Alpha

Most van electrical systems need a DC-DC charger, a solar controller, a shore charger and a battery monitor. The Manager Alpha75 does all four in one unit, which means fewer parts, less wiring and one screen to read. REDARC rates it up to 55% smaller and 28% lighter than comparable multi-part systems.

What the Alpha75 handles

  • Charge: up to 75A from any mix of alternator, solar and shore power
  • Monitor: state of charge, time left and current flow on the RedVision display or app
  • Protect the start battery: spare solar tops it up, and recovery mode helps if it goes flat

Build it into a system

We pair the Alpha75 with a 206Ah heated lithium battery and a REDARC 3000W inverter for a complete off-grid setup.

Fitment & Compatibility

Fits: Universal, 12V house battery systems

Not compatible with: 24V or 48V house battery systems

Not sure your build qualifies? Reach out to our team.

Specifications

BrandREDARC
ModelManager Alpha75 with RedVision (BMS12075-NA)
GTIN9338628010189
Charge outputUp to 75A combined from DC, AC and solar
Nominal system voltage12V
Start battery input9 to 32V DC
Solar input9 to 48V DC (array voltage must stay under 48V at the coldest temperature)
AC input95 to 264V AC, 45 to 65 Hz
Battery typesStandard lithium, heated lithium, AGM, gel, calcium, standard lead acid
MonitoringSmart Battery Monitor, ±500A measurement range
Display and appRedVision display included; RedVision app over Bluetooth 5.1, up to 138 ft
Operating temperature-4 to 140°F
Dimensions15.75 L x 6.06 W x 4.72 H in
Weight13.25 lb
MountingIndoor living areas only, within 6 ft 7 in of cable from the house battery
Made inAustralia
Warranty2 years (REDARC)
FitmentUniversal, 12V house systems

What's in the Box

  • Manager Alpha75 main unit
  • Smart Battery Monitor
  • RedVision display
  • M6 x 12 mm terminal fasteners (4)
  • M10 x 20 mm alternative terminal bolt
  • R-Bus terminating resistor
  • R-Bus (RJ45) cables, 6 ft 6 in (2)
  • Battery sense lead, 3 ft 3 in
  • Mains cable
DIY FriendlyAdvanced; professional install recommended
Drilling RequiredYes, to mount the main unit

REDARC recommends a qualified auto electrician for this install. It covers mounting the main unit, battery monitor and display, then wiring the house battery, start battery, solar, ground and shore power. Install time depends on your build. Reach out to our team at products@sandyvans.com or (619) 812-1903 for a shop install.

Mistakes to avoid

  • Mounting in the engine bay. The main unit, monitor and display are rated for indoor living areas only.
  • Long battery runs. Keep the main unit within 6 ft 7 in of cable from the house battery.
  • Blocking airflow. Leave 0.4 in at the sides and 1.6 in at each end, or 4 in all around in an enclosed space with venting.
  • Using adhesive or skipping mounting points. Use all six mounting points with screws.
  • Undersized cable or fuses. At 75A REDARC lists a 100A house battery fuse and a 125A start battery fuse, mounted within 6 in of each battery. Check the cable table in the manual for your run length.
  • Solar array voltage over 48V in cold weather.

Manual

REDARC Manager Alpha instruction manual

Tools You'll Need

  • Screwdriver set and medium flat blade (3/16 to 1/4 in)
  • Spanner set
  • Power drill
  • Pliers and cable cutters
  • Lug crimping tool for M6 lugs
  • Heat gun

Download the install instructions (PDF)

See all Sandy Vans install videos & manuals →

How to choose a battery management system

1. What voltage is your house battery?

How to choose: The Manager Alpha is for 12V house systems.

2. How much charging do you need?

How to choose: Match output to your battery bank and daily use. The Alpha75 covers most single-battery van builds; larger lithium banks or heavy loads point to the Alpha100.

3. Which charge sources will you use?

How to choose: If you'll charge from the alternator, solar and shore power, an all-in-one unit replaces three chargers.

4. How do you want to monitor it?

How to choose: A shunt-based monitor gives real state of charge. The Alpha75 includes a Smart Battery Monitor, a RedVision display and app access.

5. Where will it mount?

How to choose: Plan an indoor spot within 6 ft 7 in of the battery with room for airflow.

Before you order

  • 12V house battery confirmed
  • Battery type and size known
  • Solar array voltage checked against the 48V limit
  • Mounting spot near the battery planned
  • Cables, fuses and lugs sized

How the Manager Alpha75 stacks up

  • Output: 75A from three sources at once.
  • Monitoring: ±500A shunt, display and app.
  • Size: one 13.25 lb unit replaces several components.
  • Warranty: 2 years.
Can it charge from solar, the alternator and shore power at once?
Yes. It combines all three for up to 75A and puts solar first, which takes load off your alternator.
Does it work with lithium batteries?
Yes. It has standard and heated lithium profiles plus AGM, gel, calcium and standard lead acid. Only use the heated lithium profile on batteries with a working heater.
Will it work with a smart alternator?
Yes. The Manager Alpha has a vehicle ignition input for vans with smart alternators, as covered in REDARC's manual.
What's the solar input limit?
9 to 48V DC. Size your array so its voltage stays under 48V at the coldest temperature it will see, or the unit can be damaged.
Where can I mount it?
Inside the living area of the van, never in the engine bay. Keep it within 6 ft 7 in of cable from the house battery, leave room for airflow, and use all six mounting points.
What's the difference between the Alpha75 and Alpha100?
Charging output. The Alpha75 delivers up to 75A, the Alpha100 up to 100A. Pick the Alpha100 for larger lithium banks or heavy daily loads.
Can Sandy Vans install it?
Yes. Install time depends on your build and where the battery, solar and shore power runs land. Reach out to our team at products@sandyvans.com or (619) 812-1903.
Do you install products for customers?
Yes. Many SV products can be professionally installed at our San Diego shop. Reach out to our team to schedule. Email products@sandyvans.com or call 619-812-1903.
What is your shipping and return policy?
Most SV products ship free. For returns, see our Returns & Refunds policy or reach out to our team at products@sandyvans.com.
Can I reach a real person with questions?
Always. We are a small team in San Diego. Email products@sandyvans.com or call 619-812-1903 and you'll get a real answer, not a chatbot.
Where are you located?
9393 Trade Pl, San Diego, CA. Come visit the shop, we'd love to show you around.
Does Sandy Vans offer financing?
Yes. Many financing options are available. Set up a call with a sales associate to learn more.

Still have a question? Email the team and you'll get a real answer.

REDARC MANAGER ALPHA75 WITH REDVISION $3,499.00